Essay / Effects of Various Binders on Texture and Analysis of Pressed Powder
Table of ContentsIntroductionTime Required for Xrf AnalysisImportance of Xrf:Application of literatureIntroductionXRF is an abbreviation used for X-ray fluorescence. This is the phenomenon in which thus create a vacant space. Electrons of a higher energy level jump to fill this space, emitting radiation that is the characteristic of a specific element. The emitted energy is recorded by the detector of the XRF spectrophotometer. Say no to plagiarism. Get a tailor-made essay on “Why Violent Video Games Should Not Be Banned”? Get the original testXRF is a fast, non-destructive and accurate analytical method for determining the chemical composition of all types of materials. Quantitative and qualitative determination of elements can be carried out using XRF. The method has high precision and reproducibility. The measurement time is between a few seconds and 30 minutes and depends on the number of elements to be analyzed. XRF is a widely used method for measuring the elemental composition of rock, soil and mineral samples. Standard reference materials are constantly needed in XRF analysis to ensure the reliability of analytical results. They play an important role in the development of new analytical techniques, methodologies and new sample preparation procedures. It also plays an important role in evaluating the short and long term stability of instruments, in detecting random and/or systematic errors during routine analyses, for cross-calibration of different techniques and methodologies analysis and in inter-laboratory calibrations. (Ingamells and Pitard, 1986). All spectrophotometers are essentially composed of a sample holder, an atom excitation source and a detection system. The main function of a source in spectrophotometers is to irradiate a sample, to excite the atoms present in the sample. The emitted radiation is measured by the detector. In the XRF instrument, the excitation source is an X-ray tube. The spectrometer system is generally divided into two groups: energy dispersive system (EDXRF) and wavelength dispersive system ( WDXRF). The detection system is different in these two cases. In the EDXRF spectrometer, the detector measures different energetic characteristics emitted directly by the sample. The detector can separate the radiation from the sample into radiation emitted by their respective elements present in the sample, this is called dispersion. The element detection range is from sodium to uranium and the detection limit is good for heavy elements. In the WDXRF spectrometer there is an analysis crystal which disperses different energies. The radiation hits the crystal and diffracts in different directions. The element detection range extends from beryllium to uranium. The detection limit is good for lighter and heavier elements. The primary X-ray beam from the X-ray tube falls on the sample and interacts with the atoms in the sample. Electrons are removed from the inner layers of the atom. The movement of the inner shell electrons is due to the energy difference between the primary X-ray beam emitted by the analyzer and the binding energy of the electrons in their shell which keeps them in their orbitsappropriate. In this whole process, the energy of the X-rays is greater than the binding energy of the electrons. The eliminated electron leaves a vacuum which makes the atom unstable. Electrons from higher energy orbits jump to fill this gap by releasing radiation called secondary x-ray beam/fluorescence. The amount of energy lost is equivalent to the difference between two electronic shells, i.e. ΔE = E2-E1. Where E2 = energy of the upper shell E1 = energy of the inner shell.shells.ΔE= difference between two energy levelsThe amount of energy lost is unique to each element present in the sample and can be used to identify the elements . Individual energies are calculated by the detectors. The quantity of each element must be measured from the proportions of these individual energies. Time Required for Xrf Analysis The time taken by the sample for measurement depends on the nature of the sample and the levels of interest, i.e. what type of elements are to be analyzed and in what form . The sample must be fed into XRF. High percentage items required a few seconds while parts per million levels took a few minutes. The excitation process and the secondary X-ray emission during the de-excitation process of the atoms present in the sample occur in a small fraction of seconds. Modern portable XRF can be designed in seconds for such measurement. Generally, the duration of the measurement is between a few seconds and 30 minutes and depends on the number of elements to be analyzed. After measurement, sample analysis takes a few seconds. For detection of major elements, the sample is loaded as glass beads/fusion beads, which takes approximately eight seconds. Importance of Xrf: XRF has become a popular method of elemental analysis in geological studies. This is due to the following reasons. Preparing samples for XRF analysis is quite simple and less expensive. Measuring items in the sample is quick. It does not require a very experienced analyst. Even a trained assistant can run and manipulate the machine. The XRF method is not as expensive as the ICP method. Unlike the ICP method, it is not a sample destructive method. This method is very precise. The detection limit is very good. Application of Xrf: XRF Sample measurement method has wider applications. It can accurately measure all metals, cements, oils, polymers and plastics. Applications also include environmental analysis of water, waste, rocks and soil analysis. Limitations of Xrf: XRF cannot measure organic samples. XRF is not useful for measuring isotopes of elements. Types of sample preparation: Several methods were used for analysis. of powdered samples, such as rocks, minerals and ceramics, using x-ray fluorescence (xrf). These methods include the pellet (briquette) method (Tertian and Claisse, 1982; Feret and Jenkins, 1998; Matsumoto and Fuwa, 1979; Guevara and Verma, 1987) and the glass bead (fusion) method (Tertian and Claisse, 1982; Feret and Jenkins, 1998; Norrish and Thompson, 1990; Hua and Yap, 1994) for normal sample quantities. for small quantities of sample, the filter cake method (stankiewivez et al., 1996) which consists of filtering the suspension of powder or precipitate is used. The most widely used method among these is the pressed powder method. Because the pressed powder method is simple, takes less preparation time and is of course non-destructive. Solids and liquids can be measured analytically using xrf. Most ofSamples are in the form of circular discs with a radius between 5 and 50 mm. the sample is placed in a sample cup which is placed in the spectrometer. For the analysis of powders and liquids, special support films are used.Functions Ofa BinderThe functions of a binder are: It holds the particles together after the granule has dried and before it is finally hardened. During the drying process, the binder holds the sample particles. together while the water is removed; it continues to bind the particles together until the pellet is sufficiently heated. Classifications of Bonding Systems Binders can be defined as anything that sticks particles together and forms a mass. Some binders are specific to a particular type of material. They cannot therefore all be used in all possible applications. Therefore, binders are classified into the following five groups (Holley 1982): The binder adheres the sample particles together by forming a sticky layer on the particles. Bonding forces can be adhesive or cohesive. The binding is reversible in case of inactivating film. The binder forms a film on the surface of the sample particles and then hardens after undergoing a chemical reaction. This is a type of irreversible bond. A continuous matrix is formed by such binders in which the sample particles are incorporated. Such binders require high pressure which forces the particles to compact. The binders, when heated, emulsify to form a fluid. As it cools, it becomes hard and dry. It includes materials such as tar, pitch or wax. The bond when heated is reversible. A continuous matrix is formed by these binders. As its name suggests, it undergoes a chemical reaction that causes it to harden. The bond is irreversible. The binder undergoes a chemical reaction with the sample material and forms a strong bond with it. Such binders are specific to particular materials only and the bond is irreversible. The widely used binder is an inactive film because it retains particles without chemical reaction or compaction pressure and is effective at low dosages. The samples are weighed with the binder at a ratio of 10:1. Then the sample is pressed with a pressure of 20 tons for one minute. The MiniPress hydraulic press model PW4020/00 is used to press powder samples. An AXIOS Advance PW2404 (Philips, Netherlands) PANalytical wavelength dispersive spectrometer (WDXRF) with SuperQ software was used with a Rh tube at a maximum of 60 kV and 125 mA. Eivindson Literature Review. T and Oyvind Mikkelsen examined the issues using pressed powder for XRF analysis of ferrosilicon alloys. The problem arose due to the heterogeneity of the solidified ferrosilicone. Different distinct crystallographic phases with varying X-ray absorption and grinding properties are formed from the molten metal. This results in large particle size effects. Which in turn affects the accuracy and precision of XRF measurement and analysis. Despite this, the stability of the powder pellets was also affected. To have a pellet that is more stable and less affected by radiation, the choice of a binder is necessary. To minimize problems associated with the use of pressed powder, it is important to strictly control sample preparation routines.V. Ahadnejad et al. attempted to establish a simple and rapid analytical standard for X-ray fluorescence spectrometry. 15 typical samples of granitic rocks from the Malayer granitoid complex in western Iran were selected to obtain a standard..